  • weight: 485 g
Parameter:

Comprehensive error: 0.05% F.S
Rated output temperature drift: ≤ 0.15% F.S / 10 ℃
Output Sensitivity: 1.0 ± 0.1 mV / V
Zero drift: 0.05% F.S (1 minute)
Zero point temperature drift: 0.2% F.S / 10 ° C
Zero output: ± 0.1 mV / V
Input impedance: 1000 ± 50Ω
Output impedance: 1000 ± 50Ω
Overload capacity: 150% F.S
Recommended excitation voltage: 5-10V
Operating temperature range: -10 ~ +50 ℃
Application: for high-precision small-scale weighing for micro-automatic testing equipment, micro-weighing equipment, pushing and pulling equipment, pull pressure test
Red: E +
Black: E-
White: A-
Green: A +


Package included:

1 x Weighing Sensor Load Cell
1 x HX711 Module










HX711 Module + 20kg Aluminum Alloy Scale Weighing Sensor Load Cell Kit,HX711 Module + 20kg Aluminum Alloy Scale Weighing Sensor Load Cell Kit,HX711 Module + 20kg Aluminum Alloy Scale Weighing Sensor Load Cell Kit,HX711 Module + 20kg Aluminum Alloy Scale Weighing Sensor Load Cell Kit,HX711 Module + 20kg Aluminum Alloy Scale Weighing Sensor Load Cell Kit

More Details







customers reviews ( 10 )

4 / 5.0
5 stars 80%
4 stars 20%
3 stars 0%
2 stars 0%
1 stars 0%

By stephane

FR
ras
2022-10-27 00:00:00

By kauzen89

ZA
Received In good condition. It looks big on the picture but the actual thing is too small.
2022-05-19 00:00:00

By ladisslas

ZA
Received in good order and the courier was quick. The parcel was also well packed, thanks, but still need to test
2021-01-30 00:00:00

By WayneLaw

AU
Package arrived as described
2020-08-30 00:00:00

By Israelsatuquinga

EC
excelente para proyectos
2019-11-16 00:00:00

By uhm

DK
Tested on a Professional instrument, and accuracy is within +- 5%, acceptable for this price.
2019-02-28 00:00:00

By fuiru

US
I was able to get this working very quickly, but the values coming from the HX711, with no load on the bar, kept drifting very significantly. After a long troubleshooting session, I found out that the HX711 print has a major design flaw. They forgot to connect the AGND pin of the HX711 to GND, so it's just floating in the air, explaining the drifting. This can be fixed by soldering a wire between the GND pin on one connector and the E- pin on the other side. I found the exact same board on a different site with a picture of the schematics. This confirms that AGND is not connected to GND. See attached picture. It's also important to note that the print is designed to be supplied with 5V, even though the HX711 is specified to work down to 2.6V. The internal voltage regulator on the HX711 is configured with R12 and R13 to produce 4.2V across the sensor (E+ and E-). Considering the drop across the transistor, the supply voltage needs to be about 4.5V (or up to 5.5V), otherwise the regulator can't do its job. If a 3.3V supply is provided, the resistors can be changed accordingly. If you use it as is on 3.3V, be aware that the built-in regulator will not be able to do its job, so any ripple on the supply voltage will influence the measurement.
2018-08-01 00:00:00

By yhhca

CA
It is okay and very sensitive. it may need fine tune when putting in use. There are so many things may affect its reading.
2017-11-04 00:00:00

By VIKRANTH

IN
Nice product.
2017-10-20 00:00:00

By SiScoCsgo

FI
Nifty little 20kg load cell for measuring weight / thrust.
2017-10-19 00:00:00