Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

SKUJ97203
0 Reviews
0.00
Wholesale Prices :
Qty: 4-7 >=8
Price: 0.00 0.00
Qty:
In stock
30-day Return Policy, Learn More
Description
  • weight: 485 g

Feature:

  • 200/100/70MHz bandwidths

  • 1GSa/s Real Time sample rate

  • Large (7.0-inch) color display, WVGA(800x480)

  • Record length up to 40K

  • Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.

  • USB host and device connectivity, standard

  • Multiple automatic measurements

  • Four math functions, including FFTs standard

  • Provides software for PC real-time analysis


  • Model

    DSO5102P

    Acquisition

    Sample Rate

    Real-Time Sample: 1GS/s

    Acquisition Modes


    Normal

    Normal data only

    Peak Detect

    High-frequency and randon glith capture

    Average

    Wavefom Average, selectable 4,8,16,32,64,128

    Inputs

    Inputs Coupling

    AC, DC, GND

    Inputs Impendance

    1MΩ±2%‖20pF±3pF

    Probe Attenuation

    1X, 10X

    Supported Probe Attenuation Factor

    1X, 10X, 100X, 1000X

    Maximum Input Voltage

    CAT I and CAT II: 300VRMS (10×), Installation Category;
    CAT III: 150VRMS (1×);
    Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.

    Horizontal System

    Sample Rate Range

    500MS/s--1GS/s

    Waveform Interpolation

    (sin x)/x

    Record Length

    40K

    SEC/DIV Range

    4ns/div to 40s/div

    Sample Rate and
    Delay Time Accuracy

    ±50ppm(at over any ≥1ms time interval)

    Position Range

    20ns/div to 80us/div; (-8div x s/div) to 40ms;
    200us/div to 40s/div; (-8div x s/div) to 400s

    Time Measurement Accuracy
    (Full Bandwidth)

    Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
    >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
    Sample interval = s/div ÷ 200

    Vertical System

    Vertical Resolution

    8-bit resolution, all channel sampled simultaneously

    Position Range

    2mV/div to 10V/div

    Bandwidth

    100MHz

    Rise Time at BNC( typical)

    3.5ns

    Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled

    2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V
    500mV/div to 2V/div, ±40V; 5V/div, ±50V

    Math

    +, -, *, /, FFT

    FFT

    Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;
    1024 sample point

    Bandwidth Limit

    20MHz

    Low Frequency Response (-3db)

    ≤10Hz at BNC

    DC Gain Accuracy

    ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;
    ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div

    DC Measurement Accuracy,
    Average Acquisition Mode

    When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;
    When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div

    Volts Measurement Repeatability,
    Average Acquisition Mode

    volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions

    Trigger System

    Trigger Types

    Edge, Video, Pulse, Slope, Over time, Alternative

    Trigger Source

    CH1, CH2, EXT, EXT/5, AC Line

    Trigger Modes

    Auto, Normal, Single

    Coupling Type

    DC, AC, Noise Reject, HF Reject, LF Reject

    Trigger Sensitivity
    (Edge Trigger Type)

    DC(CH1,CH2):
    1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
    DC(EXT):
    200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
    DC(EXT/5):
    1V from DC to 100MHz;1.75V from 100MHz to 200MHz;
    AC: Attenuates signals below 10Hz;
    HF Reject: Attenuates signals above 80kHz
    LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz

    Trigger Level Range

    CH1/CH2: ±8 divisions from center of screen;
    EXT: ±1.2V;
    EXT/5:±6V

    Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns

    CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
    EXT: ± (6% of setting + 40mV);
    EXT/5: ± (6% of setting + 200mV);

    Set Level to 50%(typical)

    Operates with input signals ≥50Hz

    Video Trigger


    Video Trigger Type

    CH1, CH2: Peak-to-peak amplitude of 2 divisions;
    EXT: 400mV;
    EXT/5: 2V

    Signal Formats and Field Rates, Video Trigger Type

    Supports NTSC, PAL and SECAM broadcast systems for any field or any line

    Holdoff Range

    100ns ~ 10s

    Pulse Width Trigger


    Pulse Width Trigger Mode

    Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse

    Pulse Width Trigger Point

    Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
    Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
    Less than: The trigger point is the trailing edge.
    Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width

    Pulse Width Range

    20ns ~ 10s

    Slope Trigger


    Slope Trigger Mode

    Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope

    Slope Trigger Point

    Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
    Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
    Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
    Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.

    Time Range

    20ns ~ 10s

    Overtime Trigger


    Over Time Mode

    Rising edge or Falling edge

    Time Range

    20ns ~ 10s

    Alternative Trigger


    Trigger on CH1

    Internal Trigger: Edge, Pulse Width, Video, Slope

    Trigger on CH2

    Internal Trigger: Edge, Pulse Width, Video, Slope

    Trigger Frequency Counter

    Readout Resolution

    6 digits

    Accuracy (typical)

    ±30ppm (including all frequency reference errors and ±1 count errors)

    Frequency Range

    AC coupled, from 4Hz minimum to rated bandwidth

    Signal Source

    Pulse Width or Edge Trigger modes: all available trigger sources
    The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
    Pulse Width Trigger mode: The oscilloscope counts pulses of significant inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
    Edge Trigger mode: The oscilloscope counts all edges of sufficient and correct polarity.
    Video Trigger mode: The Frequency Counter does not work.

    Measure

    Cursor Measurement

    Voltage difference between cursors:△V
    Time difference between cursors:△T
    Reciprocal of△T in Hertz (1/ΔT)

    Auto Measuerment

    Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF

    Display

    Display Type

    7 inch 64K color TFT (diagonal liquid crystal)

    Display Resolution

    800 horizontal by 480 vertical pixels

    Display Contrast

    Adjustable (16 gears) with the progress bar

    Probe Compensator Output

    Output Voltage( typical)

    About 5Vpp into ≥1MΩ load

    Frequency(typical)

    1kHz

    Power Supply

    Supply Voltage

    100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ
    120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ

    Power Consumption

    <30W

    Fuse

    2A, T rating, 250V

    Environmental

    Temperature

    Operating: 32℉to 122℉(0℃to 50℃);
    Nonoperating: -40℉to 159.8℉(-40℃to +71℃)

    Cooling Method

    Convection

    Humidity

    +104℉or below (+40℃or below): ≤90% relative humidity;
    106℉to 122℉(+41℃to 50℃): ≤60% relative humidity

    Altitude

    Operating: Below 3,000m (10,000 feet);
    Nonoperaring: Below 15,000m(50,000 feet)

    Mechanical

    Size

    Length 385mm, Width 200mm, Height 245mm

    Weight

    3.5KG(with Packing); 2.08KG(without Packing)


Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

More Details







customers reviews ( 0 )

0 / 5.0
5 stars 0%
4 stars 0%
3 stars 0%
2 stars 0%
1 stars 0%