CJMCU-MLX90614 BCC Human Body Infrared Thermometer Non-contact Thermometer Serial Output Module

SKUF32126
1 Reviews
USD 57.99
Wholesale Prices :
Qty: 4-7 >=8
Price: $43.19 $40.79
Qty:
In stock
30-day Return Policy, Learn More
Description
  • weight: 485 g

Feature:


CJMCU-90614 is a low-cost infrared temperature module.

Working voltage 3-5v Low power consumption and small size.

Its working principle is to read infrared temperature data through single chip microcomputer, serial port (TTL level)

Communication mode output (the baud rate can be set): the baud rate of the serial port is 9600bps, 57600 and 115200bps

There are two ways of continuous output and query output, which can adapt to different working environments and connect with all single chip computers and computers.

Object distance ratio: 1.6: 1


letter of agreement:


Serial communication parameters (default baud rate value is 115200 bps, which can be set by software)

Baud rate: 9600 bps Check digit: N Data bit: 8 Stop bit: 1

Baud rate: 57600 bps Check digit: N Data bit: 8 Stop bit: 1

Baud rate: 115200 bps Check digit: N Data bit: 8 Stop bit: 1


Module output format:


Instruction length: 9


Data output format:


Byte1 frame header logo 0x66

Byte2 frame header logo 0x66

Byte3 data output mode (0x01 continuous output; 0x02 query output, default is continuous output mode)

Byte4 measurement data length (counted by Byte)

Byte5 data 1 high 8 bits

Byte6 data 1 low 8 bits

Byte7 data 2 high 8 bits

Byte8 data 2 lower 8 bits

Byte9 data parity bit (all 8 bits of data are accumulated)


Data calculation method:


Temperature = 8 bits of data high << 8 bits of data low, the result is the actual temperature multiplied by 100.

Command instruction (send to MCU, set various parameters)

Byte1 frame header logo 0x66

Byte2 frame header flag 0x66

Byte3 setting command

0x01 continuous output mode

0x02 query output mode

0x11 Set baud rate to 9600

0x12 Set the baud rate to 57600

0x13 Set the baud rate to 115200

Byte4 end of frame flag 0x56


Instructions:


The module outputs data for the serial port, connect the module to the power supply, connect the serial port (the default is 115200 baud rate, continuous transmission mode), and the serial port outputs directly. If you want to change the sending method, you can send the command 66 66 02 56 to the module, and then send the command every time, the module will return the temperature data once. If you want to change the baud rate to 9600, you can send 66 66 11 56 to the module. If you want to change the baud rate to 57600, you can send 66 66 12 56 to the module.


Note: No MCU source code is provided


Package includes:


1 x Sensor board with pins

CJMCU-MLX90614 BCC Human Body Infrared Thermometer Non-contact Thermometer Serial Output Module

CJMCU-MLX90614 BCC Human Body Infrared Thermometer Non-contact Thermometer Serial Output Module

CJMCU-MLX90614 BCC Human Body Infrared Thermometer Non-contact Thermometer Serial Output Module

CJMCU-MLX90614 BCC Human Body Infrared Thermometer Non-contact Thermometer Serial Output Module

CJMCU-MLX90614 BCC Human Body Infrared Thermometer Non-contact Thermometer Serial Output Module

CJMCU-MLX90614 BCC Human Body Infrared Thermometer Non-contact Thermometer Serial Output Module

CJMCU-MLX90614 BCC Human Body Infrared Thermometer Non-contact Thermometer Serial Output Module

CJMCU-MLX90614 BCC Human Body Infrared Thermometer Non-contact Thermometer Serial Output Module

CJMCU-MLX90614 BCC Human Body Infrared Thermometer Non-contact Thermometer Serial Output Module

CJMCU-MLX90614 BCC Human Body Infrared Thermometer Non-contact Thermometer Serial Output Module

More Details







customers reviews ( 1 )

5 / 5.0
5 stars 100%
4 stars 0%
3 stars 0%
2 stars 0%
1 stars 0%

By عبد الهادي المفلحي

SA
نشكركم على الخدمه والسرعه في الطلب
2021-01-24 00:00:00